cylindrical test equipment

This Article will show how to set channel Parallel and free channel Parallel on Neware Battery Testing System.

1.Settings → System settings

2.Display settings → Tick Set parallel and Free parallel →Click save

-  

3.Select channels that are needed to be paralleled, right click for turn on the menu, click Set parallel.

4.Parallel done

After the parallel is done, please connect all clamps from the paralleled channels to the corresponding polarity of the battery. For example, if two channels are paralleled, connect V+ and I+ test wire from two channels to the positive of the battery  and connect V- and I- from two channels to the negative of the battery.

 

Below will show how to Free Parallel

1.. Right click the paralleled channel, click Free parallel.

2.The paralleled channel is freed to single channels.

After free parallel, please also remember to free the test wires.